<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	xmlns:media="http://search.yahoo.com/mrss/" >

<channel>
	<title>presbytie &#8211; Pr. Damien Gatinel</title>
	<atom:link href="https://www.gatinel.com/tag/presbytie/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.gatinel.com</link>
	<description>Ophtalmologie</description>
	<lastBuildDate>Tue, 18 Aug 2026 22:27:15 +0000</lastBuildDate>
	<language>fr-FR</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	
	<item>
		<title>Topography and longitudinal chromatic aberration characterizations of refractive–diffractive multifocal intraocular lenses. Loicq J, Willet N, Gatinel D. JCRS, 2019</title>
		<link>https://www.gatinel.com/2019/11/topography-and-longitudinal-chromatic-aberration-characterizations-of-refractive-diffractive-multifocal-intraocular-lenses-loicq-j-willet-n-gatinel-d-jcrs-2019/</link>
					<comments>https://www.gatinel.com/2019/11/topography-and-longitudinal-chromatic-aberration-characterizations-of-refractive-diffractive-multifocal-intraocular-lenses-loicq-j-willet-n-gatinel-d-jcrs-2019/#respond</comments>
		
		<dc:creator><![CDATA[Damien Gatinel, MD, PhD]]></dc:creator>
		<pubDate>Sat, 09 Nov 2019 11:11:26 +0000</pubDate>
				<category><![CDATA[Publications et actualités]]></category>
		<category><![CDATA[aberration chromatique]]></category>
		<category><![CDATA[diffraction]]></category>
		<category><![CDATA[implant multifocal]]></category>
		<category><![CDATA[multifocality]]></category>
		<category><![CDATA[presbytie]]></category>
		<guid isPermaLink="false">https://www.gatinel.com/?p=13662</guid>

					<description><![CDATA[The optical design of multifocal intraocular lenses uses concepts that are sometimes difficult to grasp, especially when it concerns diffractive technology and chromatic aberration control. We published an article (available here) that is based on the optical bench analysis of several models of multifocal diffractive implants to describe their main optical characteristics and report their [&#8230;]]]></description>
										<content:encoded><![CDATA[<p><span style="font-weight: 400">The optical design of multifocal intraocular lenses uses concepts that are sometimes difficult to grasp, especially when it concerns <strong>diffractive technology and chromatic aberration control</strong>. We published an article (<a href="https://authors.elsevier.com/a/1a0ur39Xtp~aPN" target="_blank" rel="noopener">available here</a>) that is based on the optical bench analysis of several models of multifocal diffractive implants to describe their main optical characteristics and report their comparative performances. The underlying goal was to try to <strong>correlate the diffractive design of the studied IOL to their optical behavior</strong> in terms of <strong>power</strong> and <strong>chromatism</strong>.</span></p>
<p><a href="https://authors.elsevier.com/a/1a0ur39Xtp~aPN" target="_blank" rel="noopener"><img fetchpriority="high" decoding="async" class="alignleft wp-image-13675" src="https://www.gatinel.com/wp-content/uploads/2019/11/JCRS-Loicq-Willet-Gatinel-paper-1-475x590.png" alt="First page of the JCRS 2019 article on topography and chromatic aberration of multifocal IOLs" width="400" height="497" srcset="https://www.gatinel.com/wp-content/uploads/2019/11/JCRS-Loicq-Willet-Gatinel-paper-1-475x590.png 475w, https://www.gatinel.com/wp-content/uploads/2019/11/JCRS-Loicq-Willet-Gatinel-paper-1-768x954.png 768w, https://www.gatinel.com/wp-content/uploads/2019/11/JCRS-Loicq-Willet-Gatinel-paper-1-824x1024.png 824w, https://www.gatinel.com/wp-content/uploads/2019/11/JCRS-Loicq-Willet-Gatinel-paper-1-185x230.png 185w, https://www.gatinel.com/wp-content/uploads/2019/11/JCRS-Loicq-Willet-Gatinel-paper-1.png 1500w" sizes="(max-width: 400px) 100vw, 400px" /></a></p>
<p>&nbsp;</p>
<p><span style="font-weight: 400"> </span></p>
<p><span style="font-weight: 400">We have tried to relate these properties to the <strong>topographic study of diffractive gratings</strong> measured directly on the surface of these IOLs. We hope these results can help clinicians better understand the optical reality of these lenses, which is sometimes blurred by commercial communication and marketing.</span></p>
<p><span style="font-weight: 400">Skipping the mathematical details, one can apprehend the diffraction subtleties by learning some relatively simple rules. </span><span style="font-weight: 400">To illustrate some of the concepts discussed in this article, here are some explanatory diagrams that reflect some of the presented concepts and results. I hope that these illustrations will help the reader to become more familiar with the properties of diffractive IOLs, especially when it comes to chromatism.</span></p>
<p>&nbsp;</p>
<p><span style="font-weight: 400">Comparative analysis of the diffractive profile of two lenses can be very instructive as the diffractive profile has a strong impact on the optical properties of a given IOL. As an example, this figure shows two different bifocal IOL topologies:  <strong>Tecnis bifocal ZMB00</strong> and the <strong>Tecnis Symfony</strong>. Topography measurements were acquired using an optical profilometer (Bruker Contour GTI).</span></p>
<figure id="attachment_13663" aria-describedby="caption-attachment-13663" style="width: 590px" class="wp-caption aligncenter"><a href="https://www.gatinel.com/wp-content/uploads/2019/11/IOL-topography-profilometry-.png"><img decoding="async" class="size-medium wp-image-13663" src="https://www.gatinel.com/wp-content/uploads/2019/11/IOL-topography-profilometry--590x332.png" alt="Topographic profiles of Tecnis ZMB00 and Symfony multifocal intraocular lenses" width="590" height="332" srcset="https://www.gatinel.com/wp-content/uploads/2019/11/IOL-topography-profilometry--590x332.png 590w, https://www.gatinel.com/wp-content/uploads/2019/11/IOL-topography-profilometry--768x432.png 768w, https://www.gatinel.com/wp-content/uploads/2019/11/IOL-topography-profilometry--1024x576.png 1024w, https://www.gatinel.com/wp-content/uploads/2019/11/IOL-topography-profilometry--409x230.png 409w, https://www.gatinel.com/wp-content/uploads/2019/11/IOL-topography-profilometry-.png 1280w" sizes="(max-width: 590px) 100vw, 590px" /></a><figcaption id="caption-attachment-13663" class="wp-caption-text"><em>The graphs represent the diffractive profiles extracted from the general topology of the IOLs.</em></figcaption></figure>
<p><span style="font-weight: 400">Let&rsquo;s leave aside the difference in height of the diffractive steps for the moment and concentrate on their <strong>spacing</strong>.</span></p>
<p><span style="font-weight: 400">The pitch is inversely proportional to the addition power provided by the diffractive grating. From the depicted harmonic relation between the step widths of the two analyzed IOLs (2 steps on the Tecnis ZMB00 vs one step on the Technis Symfony) one can clearly conclude that the <strong>diffractive structure of the Symfony resembles that of a bifocal IOL</strong>, and that <strong>the addition power of the Symfony is roughly half of that of the ZMB00</strong>.</span></p>
<p><span style="font-weight: 400">In a <a href="https://www.gatinel.com/2016/04/gatinel-d-loicq-j-clinically-relevant-optical-properties-of-bifocal-trifocal-and-extended-depth-of-focus-intraocular-lenses-j-refract-surg-20161324273-80/">previous publication</a>, we have demonstrated that the Symfony, claimed to be an Extended Depth of Focus (EDoF) lens has a <strong>diffractive structure providing a power addition of +1.75 D in green light</strong>. Again, knowing that the power addition of a diffractive lens is theoretically fixed by the spacing between two consecutive diffractive steps, the number of rings observed on the Symfony is in accordance  with the theory, as <strong>9 rings</strong> were been utilized in the case of the EDoF lens, versus <strong>more than 20</strong> for the bifocal Tecnis.</span></p>
<p><span style="font-weight: 400">Another striking difference is the <strong>height of the diffractive steps</strong> between these two implants. The Symfony lens has <strong>higher steps</strong>, which are labeled with the term « <strong>echelette</strong> » by the manufacturer a semantic choice which could be motivated by the need to differentiate this diffractive grating from competing multifocal diffractive IOLs. </span></p>
<h2 id="understanding-the-consequences-of-modulating-the-height-of-the-step-of-a-diffractive-pattern-is-of-paramount-importance-to-grasp-the-chromatic-properties-of-some-multifocal-iols"><strong>Understanding the consequences of modulating the height of the step of a diffractive pattern is of paramount importance to grasp the chromatic properties of some multifocal IOLs.</strong></h2>
<p><span style="font-weight: 400">The height of the steps governs the <strong>amount of light energy distributed</strong> on each focus <em><strong>for a given wavelength</strong></em>, and the variation of the refraction index between the IOL and its surrounding medium. The energy associated with a particular focus is linked to the <strong>diffraction efficiency</strong> of the IOL for the considered wavelength. This efficiency is directly connected to the <strong>phase modulation</strong> that a considered light undergoes, when it passes through a periodic structure, such as a sawtooth grating, for instance. The phase modulation results from the difference in refractive index for the considered wavelength as it traverses the IOL and surrounding medium (aqueous humor when the IOL has been implanted).</span></p>
<figure id="attachment_13664" aria-describedby="caption-attachment-13664" style="width: 590px" class="wp-caption aligncenter"><a href="https://www.gatinel.com/wp-content/uploads/2019/11/pahse-shift-diffractive-step.png"><img decoding="async" class="size-medium wp-image-13664" src="https://www.gatinel.com/wp-content/uploads/2019/11/pahse-shift-diffractive-step-590x332.png" alt="Phase shift induced by a diffractive step and corresponding diffraction orders" width="590" height="332" srcset="https://www.gatinel.com/wp-content/uploads/2019/11/pahse-shift-diffractive-step-590x332.png 590w, https://www.gatinel.com/wp-content/uploads/2019/11/pahse-shift-diffractive-step-768x432.png 768w, https://www.gatinel.com/wp-content/uploads/2019/11/pahse-shift-diffractive-step-1024x576.png 1024w, https://www.gatinel.com/wp-content/uploads/2019/11/pahse-shift-diffractive-step-409x230.png 409w, https://www.gatinel.com/wp-content/uploads/2019/11/pahse-shift-diffractive-step.png 1280w" sizes="(max-width: 590px) 100vw, 590px" /></a><figcaption id="caption-attachment-13664" class="wp-caption-text"><em>In this example, the phase shift induced by a diffractive step is equal to 2 Pi for the considered wavelength (the equivalent optical path is equal to one wavelength). The maximum constructive interference at the output of the diffractive grating causes the deflection of the incident wavefront towards a single focus (corresponding to the 1st diffraction order). For shorter wavelengths, the phase shift induced by the same step height would be longer than 2 Pi, and this would generate an additional focus corresponding to the 2nd order of diffraction. The focal length of this 2nd order of diffraction would be equal to half of the 1st order foci focal length for that wavelength (the power /vergence would be twice). For longer wavelengths, the phase shift would be shorter than 2 Pi, and this would cause the diffraction of some of this incident light energy in the 0th order of diffraction: in the absence of another optical component, this 0th order diffracted light would not undergo any deviation).</em></figcaption></figure>
<p><span style="font-weight: 400">Diffractive optical elements have <strong>opposite color dispersion characteristics (i.e different longitudinal chromatic aberration &#8211; LCA)</strong> than refractive lenses: for a considered focus, the short-wavelength (blue) come into focus <strong>after</strong> the long-wavelength (red).</span></p>
<figure id="attachment_13665" aria-describedby="caption-attachment-13665" style="width: 590px" class="wp-caption aligncenter"><a href="https://www.gatinel.com/wp-content/uploads/2019/11/refractive-vs-diffractive-chromatism.png"><img loading="lazy" decoding="async" class="size-medium wp-image-13665" src="https://www.gatinel.com/wp-content/uploads/2019/11/refractive-vs-diffractive-chromatism-590x332.png" alt="Comparison of refractive and diffractive longitudinal chromatic aberration" width="590" height="332" srcset="https://www.gatinel.com/wp-content/uploads/2019/11/refractive-vs-diffractive-chromatism-590x332.png 590w, https://www.gatinel.com/wp-content/uploads/2019/11/refractive-vs-diffractive-chromatism-768x432.png 768w, https://www.gatinel.com/wp-content/uploads/2019/11/refractive-vs-diffractive-chromatism-1024x576.png 1024w, https://www.gatinel.com/wp-content/uploads/2019/11/refractive-vs-diffractive-chromatism-409x230.png 409w, https://www.gatinel.com/wp-content/uploads/2019/11/refractive-vs-diffractive-chromatism.png 1280w" sizes="auto, (max-width: 590px) 100vw, 590px" /></a><figcaption id="caption-attachment-13665" class="wp-caption-text"><em>The refractive index of a refractive lens depends on the wavelength considered. It increases for the shortest wavelengths and decreases for the longer wavelengths. For this reason, the blue radiation is focused closer to the lens (has more power) than the red radiation.</em><br /><em>For reasons related to the directions in which the constructive interferences, which depend on the wavelength under consideration, the color foci generated by a diffractive process appear in the reverse order than with refractive chromatism. These characteristics make it possible to consider the partial or total correction of chromatic aberration thanks to the combination of refractive and diffractive chromatic dispersion.</em></figcaption></figure>
<p><span style="font-weight: 400">The IOL material has a higher refractive index than the aqueous humor; hence, any incremental thickness of the IOL causes some <strong>optical path delay </strong>or equivalently<strong>, a shift in the phase of the considered light wave</strong>. For a given wavelength of interest, a phase difference of 2 Pi corresponds to a full-wave difference. If the <strong>height</strong> of a diffractive step is adjusted so that the phase shift is equal to <strong>2 Pi</strong> (one exact wavelength of interest of optical path delay), then all the light energy corresponding to this wavelength will be directed to the <strong>1</strong></span><strong>st</strong><span style="font-weight: 400"><strong> order foci</strong>.</span></p>
<figure id="attachment_13666" aria-describedby="caption-attachment-13666" style="width: 590px" class="wp-caption aligncenter"><a href="https://www.gatinel.com/wp-content/uploads/2019/11/phase-shift-1-pi.png"><img loading="lazy" decoding="async" class="size-medium wp-image-13666" src="https://www.gatinel.com/wp-content/uploads/2019/11/phase-shift-1-pi-590x332.png" alt="Two-pi phase shift distributing light among diffraction orders by wavelength" width="590" height="332" srcset="https://www.gatinel.com/wp-content/uploads/2019/11/phase-shift-1-pi-590x332.png 590w, https://www.gatinel.com/wp-content/uploads/2019/11/phase-shift-1-pi-768x432.png 768w, https://www.gatinel.com/wp-content/uploads/2019/11/phase-shift-1-pi-1024x576.png 1024w, https://www.gatinel.com/wp-content/uploads/2019/11/phase-shift-1-pi-409x230.png 409w, https://www.gatinel.com/wp-content/uploads/2019/11/phase-shift-1-pi.png 1280w" sizes="auto, (max-width: 590px) 100vw, 590px" /></a><figcaption id="caption-attachment-13666" class="wp-caption-text"><em>When the height of the steps causes a phase shift equal to 2 Pi (one wavelength) for the green wavelength, it is diffracted in order 1. However, the red (longer) light has also some of its diffracted energy in order 0 (the phase shift is slightly less than 2 Pi), while blue has some of its diffracted energy in order 2 (the phase shift is slightly less than 2 Pi) (these orders are not shown here). For each diffraction order,  the order of the color foci is caused by diffractive chromatism.  </em><br /><em>(nL is the refractive index of the IOL material, nA is the refractive index of aqueous humor.)</em></figcaption></figure>
<p>&nbsp;</p>
<p><span style="font-weight: 400">However, one should note at this stage that a 2 Pi phase shift scenario <strong>only applies to the wavelength of interest</strong>, which would be presumably of green color (peak of retinal sensitivity) in the context of IOL design. Longer wavelength (between green and the red extremity of the visible spectrum)  undergo a phase shift slightly less than 2 Pi and thus have some energy diffracted in the 0</span><span style="font-weight: 400">th</span><span style="font-weight: 400"> order, in addition to the 1</span><span style="font-weight: 400">st</span><span style="font-weight: 400"> order. Conversely, shorter wavelengths (between green and the violet extremity of the visible spectrum) have some energy diffracted in the 2</span><span style="font-weight: 400">nd</span><span style="font-weight: 400"> order of diffraction as they undergo a phase shift of more than 2 Pi.</span></p>
<p>&nbsp;</p>
<p><span style="font-weight: 400">Diffracting light into one single diffraction order is not very interesting in the case of a multifocality, as the purported goal of the diffractive design is to split incoming light into several foci. As one can guess, when the height of the step does <strong>not</strong> match a 2 Pi phase shift, incoming light will be diffracted in <strong>multiple consecutive diffraction orders</strong>.</span></p>
<figure id="attachment_13668" aria-describedby="caption-attachment-13668" style="width: 590px" class="wp-caption aligncenter"><a href="https://www.gatinel.com/wp-content/uploads/2019/11/phase-shfit-pi.png"><img loading="lazy" decoding="async" class="size-medium wp-image-13668" src="https://www.gatinel.com/wp-content/uploads/2019/11/phase-shfit-pi-590x332.png" alt="Phase shift below two pi splitting light between diffraction orders zero and one" width="590" height="332" srcset="https://www.gatinel.com/wp-content/uploads/2019/11/phase-shfit-pi-590x332.png 590w, https://www.gatinel.com/wp-content/uploads/2019/11/phase-shfit-pi-768x432.png 768w, https://www.gatinel.com/wp-content/uploads/2019/11/phase-shfit-pi-1024x576.png 1024w, https://www.gatinel.com/wp-content/uploads/2019/11/phase-shfit-pi-409x230.png 409w, https://www.gatinel.com/wp-content/uploads/2019/11/phase-shfit-pi.png 1280w" sizes="auto, (max-width: 590px) 100vw, 590px" /></a><figcaption id="caption-attachment-13668" class="wp-caption-text">When the height of the steps causes a phase shift of less than 2 Pi (half a wavelength in this <em>schematic depiction), the green wavelength is diffracted in order 0 and order 1. The same goes for the other wavelengths, but red is preferentially diffracted in order 0, while blue is preferentially diffracted in order 1. The recombination of the colored radiation in order 0 will be focused at the focal distance of the monofocal carrier lens as if no diffraction occurred: the chromatism of order 0 is refractive in the case of a diffractive intraocular lens whose 0th order corresponds to the far vision foci. The recombination of the colored radiations in order 1 constitutes the total of light energy focused at a focal length that is determined by the spacing of the steps of the diffractive grating and should correspond to a reading addition power in the context of a diffractive intraocular implant for presbyopia correction. The chromatism of the 1st diffraction order is naturally of diffractive type.</em><br /><em>(nL is the refractive index of the IOL material, nA is the refractive index of aqueous humor.)</em></figcaption></figure>
<p>&nbsp;</p>
<p><span style="font-weight: 400">When the phase delay introduced by the height of the diffractive step is longer than 2Pi for the wavelength of interest, the main split occurs between the 1</span><span style="font-weight: 400">st</span><span style="font-weight: 400"> and 2</span><span style="font-weight: 400">nd</span><span style="font-weight: 400"> orders of diffraction. Such design incurs higher steps than that of a diffractive IOL diffracting light of the design wavelength in the 0</span><span style="font-weight: 400">th</span><span style="font-weight: 400"> and 1</span><span style="font-weight: 400">st</span><span style="font-weight: 400"> orders of diffraction.</span></p>
<figure id="attachment_13669" aria-describedby="caption-attachment-13669" style="width: 590px" class="wp-caption aligncenter"><a href="https://www.gatinel.com/wp-content/uploads/2019/11/phase-shift-3-Pi.png"><img loading="lazy" decoding="async" class="size-medium wp-image-13669" src="https://www.gatinel.com/wp-content/uploads/2019/11/phase-shift-3-Pi-590x332.png" alt="Three-pi phase shift splitting light between diffraction orders one and two" width="590" height="332" srcset="https://www.gatinel.com/wp-content/uploads/2019/11/phase-shift-3-Pi-590x332.png 590w, https://www.gatinel.com/wp-content/uploads/2019/11/phase-shift-3-Pi-768x432.png 768w, https://www.gatinel.com/wp-content/uploads/2019/11/phase-shift-3-Pi-1024x576.png 1024w, https://www.gatinel.com/wp-content/uploads/2019/11/phase-shift-3-Pi-409x230.png 409w, https://www.gatinel.com/wp-content/uploads/2019/11/phase-shift-3-Pi.png 1280w" sizes="auto, (max-width: 590px) 100vw, 590px" /></a><figcaption id="caption-attachment-13669" class="wp-caption-text"><em>When the height of the steps causes a phase shift greater than 2 Pi (3 Pi, about 1.5 wavelengths in this schematic depiction), the green wavelength is diffracted in the order 1 and the order 2. The same goes for the other wavelengths. However, the red (longer wavelength) is</em> a little more diffracted in order 1, while blue is a little more diffracted in order 2.</figcaption></figure>
<p><span style="font-weight: 400"> The <strong>extinction of the 0</strong></span><strong>th</strong><span style="font-weight: 400"><strong> order</strong> of diffraction provides the opportunity to design diffractive multifocal lenses for which all the incoming light is diffracted into the 1</span><span style="font-weight: 400">st</span><span style="font-weight: 400">  and higher orders of diffraction.  In these orders, the focal distance of diffracted colors is dictated by diffractive chromatism (nth</span><span style="font-weight: 400"> order diffraction red foci has more power than nth</span><span style="font-weight: 400"> order blue foci), which is opposite to refractive chromatism. This “diffractive chromatism” can be used to compensate for the “refractive chromatism” of the monofocal IOL carrier alone or even the combined refractive chromatism of the cornea and the lens, a claim of the Symfony lens. </span></p>
<p><span style="font-weight: 400">The <strong>higher steps of the Symfony bifocal EDoF</strong> lens are indeed conceived to diffract green light in the<strong> 1</strong></span><strong>st</strong><span style="font-weight: 400"> and <strong>2</strong></span><strong>nd</strong><span style="font-weight: 400"> order of diffraction (phase shift &gt; 2 Pi for green light). In comparison, the <strong>lower height</strong> of the <strong>Tecnis ZMB00 bifocal diffractive steps</strong> is designed to split green light evenly between the <strong>0</strong></span><strong>th</strong><span style="font-weight: 400"> and <strong>1</strong></span><strong>st</strong><span style="font-weight: 400"> orders of diffraction.</span></p>
<p><span style="font-weight: 400"> These striking difference in the diffractive design explain the differences in the optical behavior and chromatism of the two lenses:</span></p>
<figure id="attachment_13670" aria-describedby="caption-attachment-13670" style="width: 590px" class="wp-caption aligncenter"><a href="https://www.gatinel.com/wp-content/uploads/2019/11/comparison-of-polychromatic-MTF.png"><img loading="lazy" decoding="async" class="size-medium wp-image-13670" src="https://www.gatinel.com/wp-content/uploads/2019/11/comparison-of-polychromatic-MTF-590x332.png" alt="Comparison of polychromatic MTF curves for Tecnis ZMB00 and Symfony lenses" width="590" height="332" srcset="https://www.gatinel.com/wp-content/uploads/2019/11/comparison-of-polychromatic-MTF-590x332.png 590w, https://www.gatinel.com/wp-content/uploads/2019/11/comparison-of-polychromatic-MTF-768x432.png 768w, https://www.gatinel.com/wp-content/uploads/2019/11/comparison-of-polychromatic-MTF-1024x576.png 1024w, https://www.gatinel.com/wp-content/uploads/2019/11/comparison-of-polychromatic-MTF-409x230.png 409w, https://www.gatinel.com/wp-content/uploads/2019/11/comparison-of-polychromatic-MTF.png 1280w" sizes="auto, (max-width: 590px) 100vw, 590px" /></a><figcaption id="caption-attachment-13670" class="wp-caption-text"><em>The Tecnis bifocal implant shares the light energy incident mainly between order 0 and order 1. The order 0 is focused thanks to the power of the monofocal carrier lens: the order of the color peaks of the polychromatic MTF curve for that distance focus is dictated by refractive chromatism. Order 1 (focus for near addition) is generated by a diffractive mechanism that causes the order of the peaks of the polychromatic MTF curve to be dictated by diffractive chromatism.</em><br /><em>The Tecnis bifocal EDoF Symfony implant shares the light energy mainly between the 1st and 2nd order of diffraction. The 1st order is focused thanks to the power of the monofocal carrier lens AND the addition provided by the diffractive grating. The 2nd order of diffraction creates an addition focus for intermediate vision. The location of the R, G, and B color peaks which combined create the  2 main peaks (distance and intermediate, respectively) of the polychromatic MTF curve of the Symfony is dictated by diffractive chromatism.</em></figcaption></figure>
<p><span style="font-weight: 400"> </span></p>
<p><span style="font-weight: 400">The design of the Symfony implies <strong>a reduction of the base power of the monofocal carrier</strong>, by an amount equal to the addition power of the 1</span><span style="font-weight: 400">st</span><span style="font-weight: 400"> order of diffraction! The sum of these two powers provides the nominal power of the IOL, for distance vision correction (ex: in a labeled « 22D » power IOL, the monofocal carrier contributes to 20.25D, and the 1st order to 1.75D). The chromatic aberration at this far focus will be dominated by the diffractive nature of the light focusing mechanism, and could compensate for the refractive chromatism brought the cornea.</span></p>
<p>The improvement of vision quality by LCA reduction has not yet been demonstrated. Although the results were not extrapolated to clinical relevance, we hope that this study still offers the reader a new performance metric to characterize multifocal IOLs and their different foci.</p>
<h3><a href="https://www.sciencedirect.com/science/article/pii/S0886335019304535?dgcid=author" target="_blank" rel="noopener"><em><strong>Read the paper for more information about the influence of the material hydrophilicity vs hydrophobicity and trifocality technology capacities on chromatism compensation.</strong></em></a></h3>
<p>&nbsp;</p>
<p><span style="font-weight: 400"> </span></p>
<p><span style="font-weight: 400"> </span></p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.gatinel.com/2019/11/topography-and-longitudinal-chromatic-aberration-characterizations-of-refractive-diffractive-multifocal-intraocular-lenses-loicq-j-willet-n-gatinel-d-jcrs-2019/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Gatinel D. La multifocalité pour les nuls. Réalités ophtalmologiques, mars 2017</title>
		<link>https://www.gatinel.com/2017/03/gatinel-d-multifocalite-nuls-realites-ophtalmologiques-mars-2017/</link>
					<comments>https://www.gatinel.com/2017/03/gatinel-d-multifocalite-nuls-realites-ophtalmologiques-mars-2017/#respond</comments>
		
		<dc:creator><![CDATA[Damien Gatinel, MD, PhD]]></dc:creator>
		<pubDate>Thu, 16 Mar 2017 21:00:24 +0000</pubDate>
				<category><![CDATA[Français]]></category>
		<category><![CDATA[Publications et actualités]]></category>
		<category><![CDATA[asphéricité]]></category>
		<category><![CDATA[diffraction]]></category>
		<category><![CDATA[implant multifocal]]></category>
		<category><![CDATA[multifocalité]]></category>
		<category><![CDATA[PresbyLASIK]]></category>
		<category><![CDATA[presbyte]]></category>
		<category><![CDATA[presbytie]]></category>
		<guid isPermaLink="false">https://www.gatinel.com/?p=11523</guid>

					<description><![CDATA[Cet article est consacré à la description simplifiée des principes optiques destinés à accroître la multifocalité pour la compensation de la presbytie. Les yeux concernés peuvent bénéficier de technologies multifocales réfractives ou diffractives, dont les principes communs gouvernent le design de solutions multifocales en chirurgie de la cataracte, en chirurgie réfractive et en contactologie. Télécharger:Gatinel [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>Cet article est consacré à la description simplifiée des principes optiques destinés à accroître la multifocalité pour la compensation de la presbytie. Les yeux concernés peuvent bénéficier de technologies multifocales réfractives ou diffractives, dont les principes communs gouvernent le design de solutions multifocales en chirurgie de la cataracte, en chirurgie réfractive et en contactologie.</p>
<p>Télécharger:<a href="https://www.gatinel.com/wp-content/uploads/2017/03/Gatinel-D.-La-multifocalité-pour-les-nuls.-Réalités-ophtalmologiques-mars-2017.pdf">Gatinel D. La multifocalité pour les nuls. Réalités ophtalmologiques, mars 2017</a></p>
<p><a href="https://www.gatinel.com/wp-content/uploads/2017/03/article-multifocalité-pour-les-nuls-D-Gatinel.jpg"><img loading="lazy" decoding="async" class="aligncenter size-medium wp-image-11525" src="https://www.gatinel.com/wp-content/uploads/2017/03/article-multifocalité-pour-les-nuls-D-Gatinel-411x590.jpg" alt="Couverture de l’article La multifocalité pour les nuls" width="411" height="590" srcset="https://www.gatinel.com/wp-content/uploads/2017/03/article-multifocalité-pour-les-nuls-D-Gatinel-411x590.jpg 411w, https://www.gatinel.com/wp-content/uploads/2017/03/article-multifocalité-pour-les-nuls-D-Gatinel-768x1102.jpg 768w, https://www.gatinel.com/wp-content/uploads/2017/03/article-multifocalité-pour-les-nuls-D-Gatinel-714x1024.jpg 714w, https://www.gatinel.com/wp-content/uploads/2017/03/article-multifocalité-pour-les-nuls-D-Gatinel-160x230.jpg 160w, https://www.gatinel.com/wp-content/uploads/2017/03/article-multifocalité-pour-les-nuls-D-Gatinel.jpg 1142w" sizes="auto, (max-width: 411px) 100vw, 411px" /></a></p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.gatinel.com/2017/03/gatinel-d-multifocalite-nuls-realites-ophtalmologiques-mars-2017/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Evaluation de la qualité de vision après chirurgie réfractive au laser chez les professionnels de santé. Lellouch J, Saad A, Guilbert E, GatinelD. Journal Francais d&#8217;ophtalmologie. 2016 39,849-858</title>
		<link>https://www.gatinel.com/2016/12/evaluation-de-qualite-de-vision-apres-chirurgie-refractive-laser-chez-professionnels-de-sante-lelllouch-j-saad-a-guilbert-e-gatineld-journal-francais-dophtalmologie-2016-39849-858/</link>
					<comments>https://www.gatinel.com/2016/12/evaluation-de-qualite-de-vision-apres-chirurgie-refractive-laser-chez-professionnels-de-sante-lelllouch-j-saad-a-guilbert-e-gatineld-journal-francais-dophtalmologie-2016-39849-858/#respond</comments>
		
		<dc:creator><![CDATA[Damien Gatinel, MD, PhD]]></dc:creator>
		<pubDate>Sun, 04 Dec 2016 11:21:17 +0000</pubDate>
				<category><![CDATA[Français]]></category>
		<category><![CDATA[Publications et actualités]]></category>
		<category><![CDATA[astigmatisme]]></category>
		<category><![CDATA[chirurgie de la myopie]]></category>
		<category><![CDATA[chirurgie réfractive]]></category>
		<category><![CDATA[hypermétropie]]></category>
		<category><![CDATA[LASIK]]></category>
		<category><![CDATA[PKR]]></category>
		<category><![CDATA[presbytie]]></category>
		<guid isPermaLink="false">https://www.gatinel.com/?p=11251</guid>

					<description><![CDATA[Quand ils présentent un défaut de vision (myopie, hypermétropie, astigmatisme ou presbytie), les professionnels de santé, médecins et infirmiers, ont recours à la chirurgie réfractive. L’exercice de la profession médicale nécessite une bonne qualité de vision. Nous avons cherché à évaluer la satisfaction et la qualité de vision des professionnels de santé qui ont bénéficié d’une [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>Quand ils présentent un défaut de vision (myopie, hypermétropie, astigmatisme ou presbytie), les professionnels de santé, médecins et infirmiers, ont recours à la chirurgie réfractive. L’exercice de la profession médicale nécessite une bonne qualité de vision. Nous avons cherché à <a href="https://authors.elsevier.com/a/1U8nnfHwlmPaS" target="_blank" rel="noopener"><strong>évaluer la satisfaction et la qualité de vision des professionnels de santé qui ont bénéficié d’une chirurgie réfractive au laser à la Fondation Rothschild ces 5 dernières années</strong>.</a></p>
<p id="spar0010">Nous avons effectué une étude rétrospective, monocentrique, dans laquelle ont été inclus tous les médecins, chirurgiens et infirmiers amétropes opérés de chirurgie réfractive par une procédure de chirurgie réfractive cornéenne au laser par photokeratectomie à visée réfractive (<strong>PKR</strong>) ou <em>laser-assisted keratomileusis in situ</em> (<strong>LASIK</strong>) entre juillet 2012 et février 2016. Ces praticiens de santé ont répondu de manière anonyme à un questionnaire en ligne comprenant 25 questions.</p>
<p id="spar0015">Sur les 2491 procédures de chirurgie photoablative réalisées pendant cette période, 158 patients ont été sélectionnés en tant que professionnel de santé, 131 ont reçu le questionnaire et 111 y ont répondu: 29 chirurgiens, 39 médecins spécialistes, 11 médecins généralistes et 32 infirmiers.</p>
<p><strong>91% des professionnels de santé</strong> ont indiqué <strong>être satisfaits de leur qualité de vision postopératoire</strong> <strong>et 63,9 % l’estimaient même meilleure qu’en préopératoire</strong> avec correction en lunettes ou lentilles de contact.</p>
<figure id="attachment_11254" aria-describedby="caption-attachment-11254" style="width: 590px" class="wp-caption aligncenter"><a href="https://www.gatinel.com/wp-content/uploads/2016/12/Resultat-chirurgie-refractive-chez-medecins.jpg"><img loading="lazy" decoding="async" class="size-medium wp-image-11254" src="https://www.gatinel.com/wp-content/uploads/2016/12/Resultat-chirurgie-refractive-chez-medecins-590x521.jpg" alt="Extrait des résultat du questionnaire en ligne à destination des professionnels de santé ayant bénéficié de la chirurgie réfractive." width="590" height="521" srcset="https://www.gatinel.com/wp-content/uploads/2016/12/Resultat-chirurgie-refractive-chez-medecins-590x521.jpg 590w, https://www.gatinel.com/wp-content/uploads/2016/12/Resultat-chirurgie-refractive-chez-medecins-768x679.jpg 768w, https://www.gatinel.com/wp-content/uploads/2016/12/Resultat-chirurgie-refractive-chez-medecins-1024x905.jpg 1024w, https://www.gatinel.com/wp-content/uploads/2016/12/Resultat-chirurgie-refractive-chez-medecins-260x230.jpg 260w, https://www.gatinel.com/wp-content/uploads/2016/12/Resultat-chirurgie-refractive-chez-medecins.jpg 1617w" sizes="auto, (max-width: 590px) 100vw, 590px" /></a><figcaption id="caption-attachment-11254" class="wp-caption-text">Extrait des résultat du questionnaire en ligne à destination des professionnels de santé ayant bénéficié de la chirurgie réfractive.</figcaption></figure>
<p><strong>92,8 % de ces professionnels de santé ont déclaré qu’ils referaient l’intervention</strong>, et <strong>94,6 % la conseilleraient à un proche ou un patient</strong>. L’analyse des données cliniques postopératoires a montré une bonne efficacité et prédictibilité de la procédure chirurgicale à visée réfractive.</p>
<p id="spar0020"><strong>Les médecins, chirurgiens et infirmiers opérés de chirurgie réfractive cornéenne au laser expriment la même satisfaction que la population générale, et recommanderaient cette chirurgie à leurs proches et à leurs patients.</strong></p>
<h2 id="telecharger-lire-larticle"><a href="https://authors.elsevier.com/a/1U8nnfHwlmPaS" target="_blank" rel="noopener">Télécharger/ lire l&rsquo;article : </a></h2>
<p><a href="https://www.gatinel.com/wp-content/uploads/2016/12/Evaluation-de-la-qualité-de-vision-après-chirurgie-réfractive-au-laser-chez-les-professionnels-de-santé.-Lelllouch-J-Saad-A-Guilbert-E-GatinelD.-Journal-Francais-dophtalmologie.-2016-39849-858.pdf">evaluation-de-la-qualite-de-vision-apres-chirurgie-refractive-au-laser-chez-les-professionnels-de-sante-lelllouch-j-saad-a-guilbert-e-gatineld-journal-francais-dophtalmologie-2016-39849-858</a></p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.gatinel.com/2016/12/evaluation-de-qualite-de-vision-apres-chirurgie-refractive-laser-chez-professionnels-de-sante-lelllouch-j-saad-a-guilbert-e-gatineld-journal-francais-dophtalmologie-2016-39849-858/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Comparison of 3 Diffractive IOLs in 3 Wavelengths Bifocal/ EDOF/Trifocal. D Gatinel, C Pagoulle, L Gobin, J Loicq. ASCRS meeting, 2016, May 10th</title>
		<link>https://www.gatinel.com/2016/05/comparison-of-3-diffractive-iols-in-3-wavelengths-bifocal-edoftrifocal-d-gatinel-c-pagoulle-l-gobin-j-loicq-ascrs-meeting-2016-may-10th/</link>
					<comments>https://www.gatinel.com/2016/05/comparison-of-3-diffractive-iols-in-3-wavelengths-bifocal-edoftrifocal-d-gatinel-c-pagoulle-l-gobin-j-loicq-ascrs-meeting-2016-may-10th/#respond</comments>
		
		<dc:creator><![CDATA[Damien Gatinel, MD, PhD]]></dc:creator>
		<pubDate>Sun, 15 May 2016 15:16:39 +0000</pubDate>
				<category><![CDATA[Anglais]]></category>
		<category><![CDATA[Publications et actualités]]></category>
		<category><![CDATA[chirurgie de la cataracte]]></category>
		<category><![CDATA[chirurgie de la presbytie]]></category>
		<category><![CDATA[diffraction]]></category>
		<category><![CDATA[implant multifocal]]></category>
		<category><![CDATA[implant trifocal]]></category>
		<category><![CDATA[presbytie]]></category>
		<category><![CDATA[trifocal]]></category>
		<guid isPermaLink="false">https://www.gatinel.com/?p=10803</guid>

					<description><![CDATA[This paper focuses on the objective comparison of three premium intraocular lenses (IOLs) : one said monofocal achromatic with extended depth of focus (EDOF), one bifocal diffractive, one trifocal diffractive. All IOLs are made with an hydrophobic material. &#160; &#160; Abstract : Purpose To describe the optical performances of 3 types of diffractive hydrophobic intraocular [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>This paper focuses on the objective comparison of three premium intraocular lenses (IOLs) : one said monofocal achromatic with extended depth of focus (EDOF), one bifocal diffractive, one trifocal diffractive. All IOLs are made with an hydrophobic material.<br />
<iframe loading="lazy" src="https://www.youtube.com/embed/pelonlHfEVs" width="560" height="315" frameborder="0" allowfullscreen="allowfullscreen"></iframe></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><b>Abstract :</b></p>
<p><b>Purpose</b><br />
To describe the optical performances of 3 types of diffractive hydrophobic intraocular lenses (IOLs): monofocal achromatic, bifocal and trifocal, using various visible wavelengths.</p>
<p><b>Methods</b><br />
3 IOLs were measured with an optical bench (PMTF,LambdaX,Nivelles, Belgium) to determine modulation transfer function (MTF) and point spread function (PSF). Measurements were performed at 480 nm,546 nm,650 nm using an aberration free cornea and aspheric artificial cornea generating +0.28µm positive spherical aberration by ISO11979-2 guidelines. Through-focus MTF was recorded for various pupil apertures. Evaluation of halos was performed from PSF measurements obtained at each focal spot location. Images of USAF targets were recorded with simulated distances from 1m to 25cm. Amplitude of off-axis peaks of radial profile of PSF enabled to quantify percentage of energy within the halos.</p>
<p><b>Results</b><br />
The monofocal and the bifocal IOLs presented 2 peaks on the through-focus MTF in green light: intermediate vision (at +1.75D) for the monofocal achromatic lens, and far and near vision (at +4D) for the bifocal IOL of the same material. Three peaks (Distance, Intermediate at +1.75D, Near at +3.5D) were recorded with the trifocal IOL at any wavelength. The achromatic monofocal IOL was monofocal for far vision with red light and monofocal for near vision with blue light. The influence of the cornea models was limited. The amount of halos were comparable between lenses (3 to 5 % of the enclosed central light energy).</p>
<p><b>Conclusion</b><br />
The achromatic diffractive IOL behaved like a bifocal IOL with an intermediate addition foci in green light. The bifocal and trifocal IOL induced similar chromatic effects for the near (bifocal, trifocal) and intermediate (trifocal) foci.</p>
<p>&nbsp;</p>
<p><em><strong>This paper was awarded Best Paper of Session in session <a href="http://onlinefinalprogram.ascrs.org/i/676446-2016-online-final-program/274" target="_blank" rel="noopener">4-K : PRESBYOPIA Trifocal IOLs, LASIK.</a></strong></em></p>
<p>&nbsp;</p>
<p>See also <a href="https://www.gatinel.com/2016/04/gatinel-d-loicq-j-clinically-relevant-optical-properties-of-bifocal-trifocal-and-extended-depth-of-focus-intraocular-lenses-j-refract-surg-20161324273-80/"> here</a> for more about some of these results.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.gatinel.com/2016/05/comparison-of-3-diffractive-iols-in-3-wavelengths-bifocal-edoftrifocal-d-gatinel-c-pagoulle-l-gobin-j-loicq-ascrs-meeting-2016-may-10th/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Gatinel D, Azar DT, Dumas L, Malet J. Effect of Anterior Corneal Surface  Asphericity Modification on Fourth-Order  Zernike Spherical Aberrations. J Refract Surg. 2014;30(10):708-715</title>
		<link>https://www.gatinel.com/2014/10/effect-ofgatinel-d-azar-dt-dumas-l-malet-j-anterior-corneal-surface-asphericity-modification-on-fourth-order-zernike-spherical-aberrations-j-refract-surg-20143010708-715/</link>
					<comments>https://www.gatinel.com/2014/10/effect-ofgatinel-d-azar-dt-dumas-l-malet-j-anterior-corneal-surface-asphericity-modification-on-fourth-order-zernike-spherical-aberrations-j-refract-surg-20143010708-715/#respond</comments>
		
		<dc:creator><![CDATA[Damien Gatinel, MD, PhD]]></dc:creator>
		<pubDate>Sat, 11 Oct 2014 16:45:40 +0000</pubDate>
				<category><![CDATA[Anglais]]></category>
		<category><![CDATA[Publications et actualités]]></category>
		<category><![CDATA[aberration sphérique]]></category>
		<category><![CDATA[asphéricité]]></category>
		<category><![CDATA[chirurgie de la presbytie]]></category>
		<category><![CDATA[hypermétropie]]></category>
		<category><![CDATA[LASIK]]></category>
		<category><![CDATA[presbytie]]></category>
		<guid isPermaLink="false">https://www.gatinel.com/?p=9197</guid>

					<description><![CDATA[Télécharger :JRSOnline06GATINEL(1) Cet article est consacré à l&#8217;étude des relations entre les variations de l&#8217;asphéricité et de celles de l&#8217;aberration sphérique d&#8217;origine cornéenne. En chirurgie réfractive de la presbytie, la plupart des corrections multifocales en LASIK (presbyLASIK) reposent sur la correction d&#8217;un éventuel défocus (D), et d&#8217;une modulation de l&#8217;asphéricité cornéenne (Q) pour induire une [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>Télécharger :<a href="https://www.gatinel.com/wp-content/uploads/2014/10/JRSOnline06GATINEL1.pdf">JRSOnline06GATINEL(1)</a></p>
<p>Cet article est consacré à l&rsquo;étude des relations entre les variations de l&rsquo;asphéricité et de celles de l&rsquo;aberration sphérique d&rsquo;origine cornéenne. En chirurgie réfractive de la presbytie, la plupart des corrections multifocales en LASIK (presbyLASIK) reposent sur la correction d&rsquo;un éventuel défocus (D), et d&rsquo;une modulation de l&rsquo;asphéricité cornéenne (Q) pour induire une multifocalité cornéenne provoquant une myopisation centrale et emmétropisation périphérique. Ce différentiel de réfraction correspond à de l&rsquo;aberration sphérique  (Z40) négative.</p>
<p>L&rsquo;objectif de la correction multifocale est ainsi de faire varier l&rsquo;aberration sphérique ΔZ40 vers une valeur plus négative. Pour une correction myopique (ou hypermétropique) D et une modulation souhaitée de l&rsquo;asphéricité (ΔZ40), quelle est la valeur de Q à viser pour obtenir cette correction et la variation souhaitée? Pour répondre à cette questionn un modèle mathématique a été construit ; la face antérieure de la cornée est modélisée comme une surface asphérique dont le profil est décrit par une section conique. La délivrance d&rsquo;un profil d&rsquo;ablation asphérique permet de corriger le defocus paraxial (D) et moduler l&rsquo;asphéricité cornéenne (Q). Nous avons calculé, pour diverses corrections de défocus (myopie et hypermétropie), quelle était la variation d&rsquo;asphéricité à programmer pour obtenir une variation de l&rsquo;aberration sphérique souhaitée (ex: ΔZ40 =-0.4 microns sur une zone optique de 6 mm). Le résultat principal de cette étude concerne le fait que pour les corrections de l&rsquo;hypermétropie, la variation d&rsquo;asphéricité (ΔQ) permettant d&rsquo;obtenir une variation d&rsquo;aberration sphérique (ΔZ40) de l&rsquo;ordre de -0.4 microns est relativement constante, et proche de ΔQ =-0.6. Ceci suggère la possibilité d&rsquo;établir un nomogramme simplifié pour la correction conjointe de la presbytie et de l&rsquo;hypermétropie.</p>
<p>Télécharger :</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.gatinel.com/2014/10/effect-ofgatinel-d-azar-dt-dumas-l-malet-j-anterior-corneal-surface-asphericity-modification-on-fourth-order-zernike-spherical-aberrations-j-refract-surg-20143010708-715/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>D Gatinel. Choosing the Mode of Presbyopia Correction. CRST Europe &#8211; Octobre 2013</title>
		<link>https://www.gatinel.com/2013/09/d-gatinel-choosing-the-mode-of-presbyopia-correction-crst-europe-octobre-2013/</link>
					<comments>https://www.gatinel.com/2013/09/d-gatinel-choosing-the-mode-of-presbyopia-correction-crst-europe-octobre-2013/#respond</comments>
		
		<dc:creator><![CDATA[Damien Gatinel, MD, PhD]]></dc:creator>
		<pubDate>Sat, 21 Sep 2013 15:37:23 +0000</pubDate>
				<category><![CDATA[Anglais]]></category>
		<category><![CDATA[Publications et actualités]]></category>
		<category><![CDATA[chirurgie de la presbytie]]></category>
		<category><![CDATA[chirurgie réfractive]]></category>
		<category><![CDATA[KAMRA]]></category>
		<category><![CDATA[laser excimer]]></category>
		<category><![CDATA[multifocalité]]></category>
		<category><![CDATA[presbytie]]></category>
		<category><![CDATA[trifocal]]></category>
		<guid isPermaLink="false">https://www.gatinel.com/?p=8020</guid>

					<description><![CDATA[Choix d&#8217;une technique de correction de la presbytie. Cet article est consacré à la revue des options actuelles disponibles pour la chirurgie de la presbytie. Les opérations destinées à corriger la presbytie peuvent être exercées sur la cornée (ex: presby LASIK) ou sur le cristallin (ex: ablation du cristallin et remplacement par un implant multifocal). Elles consistent [&#8230;]]]></description>
										<content:encoded><![CDATA[<h2 id="choix-dune-technique-de-correction-de-la-presbytie">Choix d&rsquo;une technique de correction de la presbytie.</h2>
<p>Cet article est consacré à la revue des options actuelles disponibles pour la chirurgie de la presbytie. Les opérations destinées à corriger la presbytie peuvent être exercées sur la cornée (ex: presby LASIK) ou sur le cristallin (ex: ablation du cristallin et remplacement par un implant multifocal). Elles consistent généralement à augmenter la profondeur de champ par le biais de l&rsquo;induction d&rsquo;une multifocalité (zones réfractives dédiées à la vision de loin ou de près, zones diffractives), ou l&rsquo;induction d&rsquo;une néo-pupille (implant intra cornéen Kamra). <a href="https://www.gatinel.com/wp-content/uploads/2013/09/D-Gatinel.-Choosing-the-mode-of-presbyopia-correction.-Cataract-and-Refractive-Surgery-Today-Octobre-2013.pdf">D Gatinel. Choosing the mode of presbyopia correction. Cataract and Refractive Surgery Today, Octobre 2013</a></p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.gatinel.com/2013/09/d-gatinel-choosing-the-mode-of-presbyopia-correction-crst-europe-octobre-2013/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>D Gatinel. Que proposer à un myope presbyte déçu des lentilles? Réalités ophtalmologiques, Mars 2012</title>
		<link>https://www.gatinel.com/2012/04/d-gatinel-que-proposer-a-un-myope-presbyte-decu-des-lentilles-realites-ophtalmologiques-mars-2012/</link>
					<comments>https://www.gatinel.com/2012/04/d-gatinel-que-proposer-a-un-myope-presbyte-decu-des-lentilles-realites-ophtalmologiques-mars-2012/#respond</comments>
		
		<dc:creator><![CDATA[Damien Gatinel, MD, PhD]]></dc:creator>
		<pubDate>Tue, 03 Apr 2012 21:52:09 +0000</pubDate>
				<category><![CDATA[Français]]></category>
		<category><![CDATA[Publications et actualités]]></category>
		<category><![CDATA[myopie]]></category>
		<category><![CDATA[presbytie]]></category>
		<guid isPermaLink="false">https://www.gatinel.com/?p=4395</guid>

					<description><![CDATA[Cet article est consacré aux  possibilités offertes par la chirurgie réfractive pour la correction de la myopie chez le presbyte. Contrairement à une idée répandue, la presbytie n&#8217;est pas une contre indication à l&#8217;opération de la myopie. Il n&#8217;y a pas d&#8217;âge limite pour réaliser une chirurgie de la myopie. Le choix de la technique [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>Cet article est consacré aux  possibilités offertes par la chirurgie réfractive pour la correction de la myopie chez le presbyte. Contrairement à une idée répandue, la presbytie n&rsquo;est pas une contre indication à l&rsquo;opération de la myopie. Il n&rsquo;y a pas d&rsquo;âge limite pour réaliser une chirurgie de la myopie. Le choix de la technique dépend des motivations du patient, du degré de la myopie et la présence d&rsquo;anomalies oculaires associées (ex: cataracte débutante).</p>
<p>Lire: <a href="https://www.gatinel.com/wp-content/uploads/2012/04/Que-proposer-a-un-myope-presbyte-d%C3%A9cu-des-lentilles1.pdf">Que proposer a un myope presbyte décu des lentilles</a></p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.gatinel.com/2012/04/d-gatinel-que-proposer-a-un-myope-presbyte-decu-des-lentilles-realites-ophtalmologiques-mars-2012/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Gatinel D. Correction de la presbytie: la multifocalité personnalisée grâce aux aberrations optiques de haut degré</title>
		<link>https://www.gatinel.com/2010/03/correction-de-la-presbytie-la-multifocalite-personnalisee-grace-aux-aberrations-optiques-de-haut-degre/</link>
					<comments>https://www.gatinel.com/2010/03/correction-de-la-presbytie-la-multifocalite-personnalisee-grace-aux-aberrations-optiques-de-haut-degre/#respond</comments>
		
		<dc:creator><![CDATA[Damien Gatinel, MD, PhD]]></dc:creator>
		<pubDate>Fri, 19 Mar 2010 20:51:46 +0000</pubDate>
				<category><![CDATA[Français]]></category>
		<category><![CDATA[Publications et actualités]]></category>
		<category><![CDATA[Twitter]]></category>
		<category><![CDATA[aberrométrie]]></category>
		<category><![CDATA[chirurgie de la presbytie]]></category>
		<category><![CDATA[multifocalité]]></category>
		<category><![CDATA[presbytie]]></category>
		<guid isPermaLink="false">https://www.gatinel.com/?p=1535</guid>

					<description><![CDATA[Cet article explique le lien entre multifocalité et aberrations optiques, lien souvent occulté par des diversions marketing à visée simplificatrices ! Télécharger l&#8217;article :Gatinel D. Correction de la presbytie: la multifocalité personnalisée grâce aux aberrations optiques de haut degré]]></description>
										<content:encoded><![CDATA[<p>Cet article explique le lien entre multifocalité et aberrations optiques, lien souvent occulté par des diversions marketing à visée simplificatrices !</p>
<p>Télécharger l&rsquo;article :<a href="https://www.gatinel.com/wp-content/uploads/2010/03/Gatinel-Multifocalité-aberrations3.pdf">Gatinel D. Correction de la presbytie: la multifocalité personnalisée grâce aux aberrations optiques de haut degré</a></p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.gatinel.com/2010/03/correction-de-la-presbytie-la-multifocalite-personnalisee-grace-aux-aberrations-optiques-de-haut-degre/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
