<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	xmlns:media="http://search.yahoo.com/mrss/" >

<channel>
	<title>profil d&rsquo;ablation &#8211; Pr. Damien Gatinel</title>
	<atom:link href="https://www.gatinel.com/tag/profil-dablation/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.gatinel.com</link>
	<description>Ophtalmologie</description>
	<lastBuildDate>Tue, 18 Aug 2026 22:25:30 +0000</lastBuildDate>
	<language>fr-FR</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	
	<item>
		<title>Qu&#8217;est-ce que la formule de Munnerlyn?</title>
		<link>https://www.gatinel.com/2011/01/quest-ce-que-la-formule-de-munnerlyn/</link>
					<comments>https://www.gatinel.com/2011/01/quest-ce-que-la-formule-de-munnerlyn/#comments</comments>
		
		<dc:creator><![CDATA[Damien Gatinel, MD, PhD]]></dc:creator>
		<pubDate>Mon, 31 Jan 2011 22:05:08 +0000</pubDate>
				<category><![CDATA[Questions fréquentes (FAQ)]]></category>
		<category><![CDATA[laser excimer]]></category>
		<category><![CDATA[profil d'ablation]]></category>
		<guid isPermaLink="false">https://www.gatinel.com/?p=2036</guid>

					<description><![CDATA[La formule de Munnerlyn est une équation qui relie l&#8217;épaisseur de cornée à retirer avec le laser excimer en chaque point pour corriger la myopie, sur une zone optique donnée. Elle est obtenue par un « développement limité » au voisinage du sommet de la cornée (la formule de Munnerlyn est une « approximation »). Charles Munnerlyn était ingénieur [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>La formule de Munnerlyn est une équation qui relie l&rsquo;épaisseur de cornée à retirer avec le laser excimer en chaque point pour corriger la myopie, sur une zone optique donnée. Elle est obtenue par un « développement limité » au voisinage du sommet de la cornée (la formule de Munnerlyn est une « approximation »). Charles Munnerlyn était ingénieur en optique et a occupé des fonctions importantes auprès de la société Visx, pionnière en matière de correction laser au Etats Unis, à la fin des années 80.</p>
<p>Cette formule simplifiée  établit que : P (profondeur d&rsquo;ablation centrale en microns) = 1/3 x D (correction de la myopie en dioptrie) x ZO<sup>2 </sup>(diamètre de la Zone Optique en millimètres) au carré.</p>
<p>Par exemple, la correction d&rsquo;une dioptrie de myopie sur une zone optique de diamètre égal à 6 mm implique une profondeur d&rsquo;ablation centrale de : P= 1/3 x 6 x 36 = 12 microns (cette estimation est légèrement inférieure à la réalité, plus proche de 14 %: il est préférable d&rsquo;ajouter environ 10% au résultat obtenu avec la formule simplifiée). La formule de Munnerlyn ne tient pas compte des variations possibles de l&rsquo;asphéricité cornéenne (les traitements asphériques induisent une profondeur d&rsquo;ablation centrale légèrement différente, selon l&rsquo;asphéricité visée).</p>
<p>L&rsquo;utilisation de la formule de Munnerlyn permet d&rsquo;estimer rapidement la profondeur du traitement d&rsquo;une myopie donnée, et d&rsquo;en apprécier la variation avec le diamètre de la zone optique. Ceci est particulièrement important en LASIK, où il faut préserver une épaisseur suffisante de cornée (voir : <a title="Lasik et épaisseur de la cornée" href="https://www.gatinel.com/chirurgie-refractive/les-techniques-operatoires/lasik-technique-avec-decoupe-de-capot/lasik-et-epaisseur-de-la-cornee/">LASIK et épaisseur de cornée</a>).</p>
<figure id="attachment_2037" aria-describedby="caption-attachment-2037" style="width: 590px" class="wp-caption aligncenter"><a href="https://www.gatinel.com/wp-content/uploads/2011/01/Formule-de-Munnerlyn-site-D-Gatinel.jpg"><img fetchpriority="high" decoding="async" class="size-medium wp-image-2037" title="Formule de Munnerlyn site D Gatinel" alt="Formule de Munnerlyn site D Gatinel" src="https://www.gatinel.com/wp-content/uploads/2011/01/Formule-de-Munnerlyn-site-D-Gatinel-590x442.jpg" width="590" height="442" srcset="https://www.gatinel.com/wp-content/uploads/2011/01/Formule-de-Munnerlyn-site-D-Gatinel-590x442.jpg 590w, https://www.gatinel.com/wp-content/uploads/2011/01/Formule-de-Munnerlyn-site-D-Gatinel.jpg 720w" sizes="(max-width: 590px) 100vw, 590px" /></a><figcaption id="caption-attachment-2037" class="wp-caption-text">La formule de Munnerlyn est issue du calcul analytique de la distance entre deux cornées modélisées par des coupoles sphériques, dont les rayons de courbures diffèrent (la profil de la première cornée- cercle plus petit &#8211; est celui de la cornée en préopératoire, et le second celui de la cornée en postopératoire; cette cornée possède un plus grand rayon, car elle est forcément plus plate pour un traitement de myopie. La différence de puissance optique entre ces cornées correspond à la valeur de la myopie à corriger !).</figcaption></figure>
<p>La publication de l&rsquo;article mentionnant les principes de la photoablation démyopisante remonte à 1988, soit deux ans avant l&rsquo;<a title="Histoire du LASIK" href="https://www.gatinel.com/chirurgie-refractive/les-techniques-operatoires/lasik-technique-avec-decoupe-de-capot/histoire-du-lasik/">introduction de la technique du LASIK.</a></p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.gatinel.com/2011/01/quest-ce-que-la-formule-de-munnerlyn/feed/</wfw:commentRss>
			<slash:comments>1</slash:comments>
		
		
			</item>
		<item>
		<title>Gatinel D, Hoang-Xuan T. Geometric customization of optical and transition zone parameters for treatment of compound myopic astigmatism with the NIDEK EC-5000 excimer laser</title>
		<link>https://www.gatinel.com/2007/01/gatinel-d-hoang-xuan-t-geometric-customization-of-optical-and-transition-zone-parameters-for-treatment-of-compound-myopic-astigmatism-with-the-nidek-ec-5000-excimer-laser/</link>
					<comments>https://www.gatinel.com/2007/01/gatinel-d-hoang-xuan-t-geometric-customization-of-optical-and-transition-zone-parameters-for-treatment-of-compound-myopic-astigmatism-with-the-nidek-ec-5000-excimer-laser/#respond</comments>
		
		<dc:creator><![CDATA[Damien Gatinel, MD, PhD]]></dc:creator>
		<pubDate>Thu, 11 Jan 2007 08:48:46 +0000</pubDate>
				<category><![CDATA[Anglais]]></category>
		<category><![CDATA[Publications et actualités]]></category>
		<category><![CDATA[astigmatisme]]></category>
		<category><![CDATA[laser excimer]]></category>
		<category><![CDATA[LASIK]]></category>
		<category><![CDATA[profil d'ablation]]></category>
		<guid isPermaLink="false">http://gatinel.studiocassette.com/?p=404</guid>

					<description><![CDATA[J Refract Surg. 2007;23 (9): 924-30 Cet article illustre l&#8217;intérêt de l&#8217;optimisation de la géométrie des zones optiques et de transition dans le traitement par LASIK de l&#8217;astigmatisme myopique. Les zones optiques et de transition de pourtour ovale ou elliptique procurent de meilleurs résultats réfractifs. Télécharger l&#8217;article : Geometric customization of Optical and Transition Zone [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>J Refract Surg. 2007;23 (9): 924-30</p>
<p>Cet article illustre l&rsquo;intérêt de l&rsquo;optimisation de la géométrie des zones optiques et de transition dans le traitement par LASIK de l&rsquo;astigmatisme myopique. Les zones optiques et de transition de pourtour ovale ou elliptique procurent de meilleurs résultats réfractifs.</p>
<p>Télécharger l&rsquo;article : <a href="http://ww.gatinel.com/wp-content/uploads/2010/01/Geometric-customization-of-Optical-and-Transition-Zone-For-Astigmatism.pdf" target="_blank" rel="noopener">Geometric customization of Optical and Transition Zone For Astigmatism</a></p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.gatinel.com/2007/01/gatinel-d-hoang-xuan-t-geometric-customization-of-optical-and-transition-zone-parameters-for-treatment-of-compound-myopic-astigmatism-with-the-nidek-ec-5000-excimer-laser/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Gatinel D, Malet J, Hoang-Xuan T, Azar DT. Corneal asphericity change after excimer laser hyperopic surgery: theoretical effects on corneal profiles and corresponding Zernike expansions</title>
		<link>https://www.gatinel.com/2004/05/gatinel-d-malet-j-hoang-xuan-t-azar-dt-corneal-asphericity-change-after-excimer-laser-hyperopic-surgery-theoretical-effects-on-corneal-profiles-and-corresponding-zernike-expansions/</link>
					<comments>https://www.gatinel.com/2004/05/gatinel-d-malet-j-hoang-xuan-t-azar-dt-corneal-asphericity-change-after-excimer-laser-hyperopic-surgery-theoretical-effects-on-corneal-profiles-and-corresponding-zernike-expansions/#respond</comments>
		
		<dc:creator><![CDATA[Damien Gatinel, MD, PhD]]></dc:creator>
		<pubDate>Sat, 01 May 2004 08:04:16 +0000</pubDate>
				<category><![CDATA[Anglais]]></category>
		<category><![CDATA[Publications et actualités]]></category>
		<category><![CDATA[hypermétropie]]></category>
		<category><![CDATA[profil d'ablation]]></category>
		<guid isPermaLink="false">http://gatinel.studiocassette.com/?p=430</guid>

					<description><![CDATA[Invest Ophthalmol Vis Sci. 2004 May;45(5):1349-59 Conversion des données du profil  cornéen en termes de Zernike, application au traitement de l&#8217;hypermétropie (IOVS, 2004, Anglais) Télécharger l&#8217;article : IOVS 2004]]></description>
										<content:encoded><![CDATA[<p>Invest Ophthalmol Vis Sci. 2004 May;45(5):1349-59<em></em></p>
<p><em></em>Conversion des données du profil  cornéen en termes de Zernike, application au traitement de l&rsquo;hypermétropie (IOVS, 2004, Anglais)</p>
<p>Télécharger l&rsquo;article : <a href="http://ww.gatinel.com/wp-content/uploads/2010/01/IOVS-2004.pdf" target="_blank" rel="noopener">IOVS 2004</a></p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.gatinel.com/2004/05/gatinel-d-malet-j-hoang-xuan-t-azar-dt-corneal-asphericity-change-after-excimer-laser-hyperopic-surgery-theoretical-effects-on-corneal-profiles-and-corresponding-zernike-expansions/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Gatinel D, Hoang-Xuan T, Azar DT. Volume estimation of excimer laser tissue ablation for correction of spherical myopia and hyperopia</title>
		<link>https://www.gatinel.com/2002/05/gatinel-d-hoang-xuan-t-azar-dt-volume-estimation-of-excimer-laser-tissue-ablation-for-correction-of-spherical-myopia-and-hyperopia/</link>
					<comments>https://www.gatinel.com/2002/05/gatinel-d-hoang-xuan-t-azar-dt-volume-estimation-of-excimer-laser-tissue-ablation-for-correction-of-spherical-myopia-and-hyperopia/#respond</comments>
		
		<dc:creator><![CDATA[Damien Gatinel, MD, PhD]]></dc:creator>
		<pubDate>Wed, 01 May 2002 08:01:26 +0000</pubDate>
				<category><![CDATA[Anglais]]></category>
		<category><![CDATA[Publications et actualités]]></category>
		<category><![CDATA[myopie]]></category>
		<category><![CDATA[profil d'ablation]]></category>
		<guid isPermaLink="false">http://gatinel.studiocassette.com/?p=427</guid>

					<description><![CDATA[Invest Ophthalmol Vis Sci. 2002 May;43(5):1445-9 Calcul du volume de tissu cornéen retiré pour la correction de la myopie et de l&#8217;hypermétropie (IOVS, 2002, Anglais) Télécharger l&#8217;article : IOVS 2002 Volumes]]></description>
										<content:encoded><![CDATA[<p>Invest Ophthalmol Vis Sci. 2002 May;43(5):1445-9<em></em></p>
<p><em></em>Calcul du volume de tissu cornéen retiré pour la correction de la myopie et de l&rsquo;hypermétropie (IOVS, 2002, Anglais)</p>
<p>Télécharger l&rsquo;article : <a href="https://www.gatinel.com/wp-content/uploads/2010/01/IOVS-2002-Volumes.pdf">IOVS 2002 Volumes</a></p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.gatinel.com/2002/05/gatinel-d-hoang-xuan-t-azar-dt-volume-estimation-of-excimer-laser-tissue-ablation-for-correction-of-spherical-myopia-and-hyperopia/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Gatinel D, Malet J, Hoang-Xuan T, Azar DT. Analysis of customized corneal ablations: theoretical limitations of increasing negative asphericity</title>
		<link>https://www.gatinel.com/2002/04/gatinel-d-malet-j-hoang-xuan-t-azar-dt-analysis-of-customized-corneal-ablations-theoretical-limitations-of-increasing-negative-asphericity/</link>
					<comments>https://www.gatinel.com/2002/04/gatinel-d-malet-j-hoang-xuan-t-azar-dt-analysis-of-customized-corneal-ablations-theoretical-limitations-of-increasing-negative-asphericity/#respond</comments>
		
		<dc:creator><![CDATA[Damien Gatinel, MD, PhD]]></dc:creator>
		<pubDate>Mon, 01 Apr 2002 07:59:47 +0000</pubDate>
				<category><![CDATA[Anglais]]></category>
		<category><![CDATA[Publications et actualités]]></category>
		<category><![CDATA[asphéricité]]></category>
		<category><![CDATA[cornée]]></category>
		<category><![CDATA[profil d'ablation]]></category>
		<guid isPermaLink="false">http://gatinel.studiocassette.com/?p=423</guid>

					<description><![CDATA[Invest Ophthalmol Vis Sci. 2002 Apr;43(4):941-8. Effet de la prise en compte de l&#8217;asphéricité prolate de la cornée sur la prondeur d&#8217;ablation pour le traitement de la myopie (IOVS, 2002, Anglais) Télécharger l&#8217;article : IOVS 2002 Negative Asphericity]]></description>
										<content:encoded><![CDATA[<p>Invest Ophthalmol Vis Sci. 2002 Apr;43(4):941-8.</p>
<p>Effet de la prise en compte de l&rsquo;asphéricité prolate de la cornée sur la prondeur d&rsquo;ablation pour le traitement de la myopie (IOVS, 2002, Anglais)</p>
<p>Télécharger l&rsquo;article : <a href="https://www.gatinel.com/wp-content/uploads/2010/01/IOVS-2002-Negative-Asphericity.pdf">IOVS 2002 Negative Asphericity</a></p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.gatinel.com/2002/04/gatinel-d-malet-j-hoang-xuan-t-azar-dt-analysis-of-customized-corneal-ablations-theoretical-limitations-of-increasing-negative-asphericity/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Gatinel D, Hoang-Xuan T. Three-dimensionnal representation and descriptive geometry of the pure spherical and pure cylindrical profiles of Excimer photoablation</title>
		<link>https://www.gatinel.com/2002/03/gatinel-d-hoang-xuan-t-three-dimensionnal-representation-and-descriptive-geometry-of-the-pure-spherical-and-pure-cylindrical-profiles-of-excimer-photoablation/</link>
					<comments>https://www.gatinel.com/2002/03/gatinel-d-hoang-xuan-t-three-dimensionnal-representation-and-descriptive-geometry-of-the-pure-spherical-and-pure-cylindrical-profiles-of-excimer-photoablation/#respond</comments>
		
		<dc:creator><![CDATA[Damien Gatinel, MD, PhD]]></dc:creator>
		<pubDate>Fri, 01 Mar 2002 09:27:46 +0000</pubDate>
				<category><![CDATA[Français]]></category>
		<category><![CDATA[Publications et actualités]]></category>
		<category><![CDATA[astigmatisme]]></category>
		<category><![CDATA[profil d'ablation]]></category>
		<guid isPermaLink="false">http://gatinel.studiocassette.com/?p=438</guid>

					<description><![CDATA[J Fr Ophtalmol. 2002 Mar;25(3):247-56 Modélisation tri-dimensionelle des contraintes géométriques du traitement  de l&#8217;astigmatisme sur la surface cornéenne (JFO, 2002, Francais). Télécharger l&#8217;article : JFO astigmatisme]]></description>
										<content:encoded><![CDATA[<p>J Fr Ophtalmol. 2002 Mar;25(3):247-56</p>
<p>Modélisation tri-dimensionelle des contraintes géométriques du traitement  de l&rsquo;astigmatisme sur la surface cornéenne (JFO, 2002, Francais).</p>
<p>Télécharger l&rsquo;article : <a href="https://www.gatinel.com/wp-content/uploads/2010/01/JFO-astigmatisme.pdf">JFO astigmatisme</a></p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.gatinel.com/2002/03/gatinel-d-hoang-xuan-t-three-dimensionnal-representation-and-descriptive-geometry-of-the-pure-spherical-and-pure-cylindrical-profiles-of-excimer-photoablation/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Gatinel D, Hoang-Xuan T, Azar DT. Three-dimensional representation and qualitative comparisons of the amount of tissue ablation to treat mixed and compound astigmatism</title>
		<link>https://www.gatinel.com/2002/01/gatinel-d-hoang-xuan-t-azar-dt-three-dimensional-representation-and-qualitative-comparisons-of-the-amount-of-tissue-ablation-to-treat-mixed-and-compound-astigmatism/</link>
					<comments>https://www.gatinel.com/2002/01/gatinel-d-hoang-xuan-t-azar-dt-three-dimensional-representation-and-qualitative-comparisons-of-the-amount-of-tissue-ablation-to-treat-mixed-and-compound-astigmatism/#respond</comments>
		
		<dc:creator><![CDATA[Damien Gatinel, MD, PhD]]></dc:creator>
		<pubDate>Fri, 11 Jan 2002 08:55:29 +0000</pubDate>
				<category><![CDATA[Anglais]]></category>
		<category><![CDATA[Publications et actualités]]></category>
		<category><![CDATA[astigmatisme]]></category>
		<category><![CDATA[profil d'ablation]]></category>
		<guid isPermaLink="false">http://gatinel.studiocassette.com/?p=416</guid>

					<description><![CDATA[J Cataract Refract Surg. 2002 Nov;28(11):2026-34 Modélisation tri dimensionelle du traitement de l&#8217;astigmatisme et comparaison des volumes photoablatés selon des stratégies de traintement en cylindre positif et négatif. Télécharger l&#8217;article : three-dimensional representation astigmatism]]></description>
										<content:encoded><![CDATA[<p>J Cataract Refract Surg. 2002 Nov;28(11):2026-34</p>
<p>Modélisation tri dimensionelle du traitement de l&rsquo;astigmatisme et comparaison des volumes photoablatés selon des stratégies de traintement en cylindre positif et négatif.</p>
<p>Télécharger l&rsquo;article : <a href="https://www.gatinel.com/wp-content/uploads/2010/01/three-dimensional-representation-astigmatism.pdf">three-dimensional representation astigmatism</a></p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.gatinel.com/2002/01/gatinel-d-hoang-xuan-t-azar-dt-three-dimensional-representation-and-qualitative-comparisons-of-the-amount-of-tissue-ablation-to-treat-mixed-and-compound-astigmatism/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Gatinel D, Hoang-Xuan T, Azar DT. Determination of corneal asphericity after myopia surgery with the excimer laser: a mathematical model</title>
		<link>https://www.gatinel.com/2001/07/gatinel-d-hoang-xuan-t-azar-dt-determination-of-corneal-asphericity-after-myopia-surgery-with-the-excimer-laser-a-mathematical-model/</link>
					<comments>https://www.gatinel.com/2001/07/gatinel-d-hoang-xuan-t-azar-dt-determination-of-corneal-asphericity-after-myopia-surgery-with-the-excimer-laser-a-mathematical-model/#respond</comments>
		
		<dc:creator><![CDATA[Damien Gatinel, MD, PhD]]></dc:creator>
		<pubDate>Wed, 11 Jul 2001 07:58:00 +0000</pubDate>
				<category><![CDATA[Anglais]]></category>
		<category><![CDATA[Publications et actualités]]></category>
		<category><![CDATA[asphéricité]]></category>
		<category><![CDATA[myopie]]></category>
		<category><![CDATA[profil d'ablation]]></category>
		<guid isPermaLink="false">http://gatinel.studiocassette.com/?p=420</guid>

					<description><![CDATA[Invest Ophthalmol Vis Sci. 2001 Jul;42(8):1736-42. Devenir de l&#8217;asphéricité cornéenne après chirurgie de la myopie (IOVS, 2001, Anglais) Télécharger l&#8217;article : IOVS 2001]]></description>
										<content:encoded><![CDATA[<p>Invest Ophthalmol Vis Sci. 2001 Jul;42(8):1736-42.</p>
<p>Devenir de l&rsquo;asphéricité cornéenne après chirurgie de la myopie (IOVS, 2001, Anglais)</p>
<p>Télécharger l&rsquo;article : <a href="https://www.gatinel.com/wp-content/uploads/2010/01/IOVS-2001.pdf">IOVS 2001</a></p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.gatinel.com/2001/07/gatinel-d-hoang-xuan-t-azar-dt-determination-of-corneal-asphericity-after-myopia-surgery-with-the-excimer-laser-a-mathematical-model/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
