Publications & actualités
keratocone
-
Quantitative comparison of corneal surface areas in keratoconus and normal eyes. FX Crahay, G. Debellemanière,S. Tobalem, W. Ghazal, S. Moran,D Gatinel. Sci Rep. 2021; 11: 6840.
Lire l’article → : Quantitative comparison of corneal surface areas in keratoconus and normal eyes. FX Crahay, G. Debellemanière,S. Tobalem, W. Ghazal, S. Moran,D Gatinel. Sci Rep. 2021; 11: 6840.Lire sur ce lien: https://www.nature.com/articles/s41598-021-86185-3 Le kératocône est caractérisé par un amincissement progressif et une déformation de la cornée responsable d’un astigmatisme…
-
Incorrect sleeping position and eye rubbing in patients with unilateral or highly asymmetric keratoconus: a case-control study A Mazharian, C Panthier, R Courtin, C Jung, R Rampat, A Saad, D Gatinel. Graefe’s Archive for Clinical and Experimental Ophthalmology (2020)
Lire l’article → : Incorrect sleeping position and eye rubbing in patients with unilateral or highly asymmetric keratoconus: a case-control study A Mazharian, C Panthier, R Courtin, C Jung, R Rampat, A Saad, D Gatinel. Graefe’s Archive for Clinical and Experimental Ophthalmology (2020)This case-control study aimed to identify new risk factors associated with Unilateral or Highly Asymmetric Keratoconus (UHAKC). The results showed a…
-
Repenser le Kératocône en 2020 – Réalités Ophtalmologiques n°269
Lire l’article → : Repenser le Kératocône en 2020 – Réalités Ophtalmologiques n°269Ce dossier paru récemment expose les avancées récentes dans la compréhension des mécanismes impliqués dans la genèse et l’évolution du kératocône et…
-
Keratoconus, what’s the rub? Cataract and Refractive Surgery Today Eu, April 2017
Lire l’article → : Keratoconus, what’s the rub? Cataract and Refractive Surgery Today Eu, April 2017In this paper, Keratoconus What’s the rub, D Gatinel, CRST Europe, April 2017, I elaborate on the hypothesis that eye rubbing is the root…
-
Que faire devant la découverte d’un kératocône ?
Lire l’article → : Que faire devant la découverte d’un kératocône ?Cette page fournit les informations nécessaires pour faire face au diagnostic de kératocône uni ou bilatéral. Le diagnostic de kératocône est souvent…
-
Gatinel D. Les frottements répétés sont ils la cause nécessaire et suffisante du kératocône? Réalités Ophtalmologiques #234, Septembre 2016
Lire l’article → : Gatinel D. Les frottements répétés sont ils la cause nécessaire et suffisante du kératocône? Réalités Ophtalmologiques #234, Septembre 2016Le kératocône est considéré comme une dystrophie cornéenne d’origine inconnue. Cet article reprend le contenu d’un article publié récemment en anglais (Eye…
-
Eye rubbing: a sine qua non for keratoconus? D Gatinel. Int K Kerat Ect Cor Dis, 2016;5(1):6-12
Lire l’article → : Eye rubbing: a sine qua non for keratoconus? D Gatinel. Int K Kerat Ect Cor Dis, 2016;5(1):6-12(Link to the original article here) download : Eye rubbing a sine qua non for keratoconus Eye rubbing as the root cause…
-
Repeatability of keratometry measurements obtained with 3 topographers in keratoconic and normal corneas. Guilbert E, Saad A, Elluard M, Grise-Dulac A, Rouger H, Gatinel D. Journal of Refractive Surgery, April 2016.
Lire l’article → : Repeatability of keratometry measurements obtained with 3 topographers in keratoconic and normal corneas. Guilbert E, Saad A, Elluard M, Grise-Dulac A, Rouger H, Gatinel D. Journal of Refractive Surgery, April 2016.Repeatability of keratometry measurements obtained with 3 topographers in keratoconic and normal corneas. Emmanuel Guilbert, MD ; Alain Saad, MD ; Maud Elluard, MD ;…
-
Validation of an objective scoring system for forme fruste keratoconus detection and post-LASIK ectasia risk assessment in Asian Eyes. Chan C, Ang M, Saad A, Chua D, Mejia M, Lim L, Gatinel D. Cornea, 2015
Lire l’article → : Validation of an objective scoring system for forme fruste keratoconus detection and post-LASIK ectasia risk assessment in Asian Eyes. Chan C, Ang M, Saad A, Chua D, Mejia M, Lim L, Gatinel D. Cornea, 2015Cet article concerne les résultat de l’évaluation du logiciel SCORE Analyzer (topographe Orbscan) sur des yeux asiatiques pour la détection des formes…
-
Gatinel D. The mystery of collagen cross linking when it comes to in vivo biomechanical measurements. J Refract Surg. 2014;30(11)-727
Lire l’article → : Gatinel D. The mystery of collagen cross linking when it comes to in vivo biomechanical measurements. J Refract Surg. 2014;30(11)-727Cette lettre à l’éditeur du Journal of Refractive Surgery concerne un article récemment publié sur les résultats du Cross Linking chez des…
-
D Gatinel. Effectiveness of corneal collagen crosslinking in vivo for corneal stiffening. J Cataract Refract Surg 2014 40,111943-1944
Lire l’article → : D Gatinel. Effectiveness of corneal collagen crosslinking in vivo for corneal stiffening. J Cataract Refract Surg 2014 40,111943-1944Cet article concerne une publication récente relative à la comparaison entre deux techniques de cross linking (XCL): conventionnelle et accélérée (l’énergie ultraviolette…
-
Le cross-linking du collagène cornéen est-il réellement efficace pour le kératocône ?
Lire l’article → : Le cross-linking du collagène cornéen est-il réellement efficace pour le kératocône ?Le cross-linking (CXL) du collagène cornéen est une technique chirurgicale proposée depuis quelques années pour solidifier la cornée des patients atteints…